Quality Control in 3D Printing: Accuracy Analysis of 3D-Printed Models of Patient-Specific Anatomy

2021

As comparative data on the precision of 3D-printed anatomical models are sparse, the aim of this study was to evaluate the accuracy of 3D-printed models of vascular anatomy generated by two commonly used printing technologies. Thirty-five 3D models of large (aortic, wall thickness of 2 mm, n = 30) and small (coronary, wall thickness of 1.25 mm, n = 5) vessels printed with fused deposition modeling (FDM) (rigid, n = 20) and PolyJet (flexible, n = 15) technology were subjected to high-resolution CT scans. From the resulting DICOM (Digital Imaging and Communications in Medicine) dataset, an STL file was generated and wall thickness as well as surface congruency were compared with the original …

3d printedMaterials science3D printing3d modelFDM printing030204 cardiovascular system & hematologylcsh:TechnologyArticle030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciencesDICOM3D engineering0302 clinical medicinelawStl fileGeneral Materials Sciencelcsh:Microscopycoronarylcsh:QC120-168.85anatomical modellcsh:QH201-278.5Fused deposition modelingaccuracyPolyJet printinglcsh:Tbusiness.industryAnatomy3D printingPatient specificaortalcsh:TA1-2040lcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringlcsh:Engineering (General). Civil engineering (General)Wall thicknessbusinesslcsh:TK1-9971Materials
researchProduct

Comparative analysis of trueness between conventional and digital impression in dental-supported fixed dental prosthesis with vertical preparation

2020

Biologically oriented preparation technique (BOPT) is a vertical preparation technique without a finish line to create a new anatomic crown with a prosthetic emergence profile. This case report describe the protocol realized digitally in a patient who required a new fixed partial denture (FPD) in the anterior esthetic zone. After time of temporary restoration, definitive conventional (CI) (double-cord retraction and vinyl polysiloxane material), and digital impression (DI) with three different intraoral scanner (IOS) (Trios®, True Definition® and iTero®) were taken. All digital impression were obtained through three different scans: temporary restoration in the mouth after healing period, p…

OrthodonticsIntraoral scannerScannerProsthetic DentistryComputer sciencemedicine.medical_treatmentDental prosthesisTemporary restorationCase Report030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Crown (dentistry)Impression03 medical and health sciences0302 clinical medicineUNESCO::CIENCIAS MÉDICASmedicineStl file030212 general & internal medicineProsthodonticsGeneral Dentistry